MetroCluster – Deleting a mirrored aggregate

This topic covers how a mirrored aggregate can be off lined and destroyed.

Destroying a mirrored aggregate
Remove a plex from a mirrored aggregate
Offline a plex
Destroy a plex
Offline the remaining plex
Destroy the aggregate

1.     Remove a plex from a mirrored aggregate

An example of a mirrored aggregate

Capacity details as with any aggregate

test1*> df -A -t aggr1
Aggregate total used avail capacity
aggr1 23TB 2TB 21TB 9%
aggr1/.snapshot 1TB 0TB 1TB 0%

RAID status of the mirrored aggregate with both plexes

test1> aggr status -r aggr1
Aggregate aggr1 (online, raid_dp, mirrored) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch03:11.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
parity switch03:12.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.32 0b 2 0 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:14.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:15.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:16.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:17.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:18.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:19.48 0b 3 0 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:20.48 0a 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:16.48 0b 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:17.48 0a 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:18.48 0c 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:11.33 0a 2 1 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:12.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688

RAID group /aggr1/plex0/rg1 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch04:15.33 0b 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
parity switch04:20.49 0d 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:16.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:17.33 0a 2 1 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:18.33 0b 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:14.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.34 0d 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:19.49 0c 3 1 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:12.42 0b 2 10 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:11.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:16.49 0a 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:17.49 0b 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:18.49 0d 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:15.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:20.50 0b 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:16.34 0c 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688

RAID group /aggr1/plex0/rg2 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch03:17.34 0c 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
parity switch03:18.34 0a 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.35 0b 2 3 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:14.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:16.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:19.54 0b 3 6 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:20.51 0d 3 3 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:12.43 0d 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:11.38 0d 2 6 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:15.35 0d 2 3 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:17.50 0d 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:18.50 0b 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:16.50 0b 3 2 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:17.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:18.42 0b 2 10 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.44 0d 2 12 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688

RAID group /aggr1/plex0/rg3 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch04:14.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
parity switch04:16.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:13.45 0b 2 13 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:18.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:20.56 0c 3 8 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch04:17.54 0b 3 6 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096
data switch03:11.44 0a 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:15.36 0c 2 4 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:17.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch04:16.44 0d 2 12 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:18.44 0c 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
data switch03:11.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688

Plex /aggr1/plex1 (online, normal, active, pool1)
RAID group /aggr1/plex1/rg0 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch01:10.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
parity switch01:11.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:12.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:4.16 0a 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:5.16 0b 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:6.22 0d 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:7.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:8.16 0d 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:13.48 0d 3 0 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:11.59 0b 3 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:12.49 0b 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:10.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:11.17 0d 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:12.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:4.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:5.17 0a 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688

RAID group /aggr1/plex1/rg1 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch01:6.23 0c 1 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
parity switch02:7.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:8.17 0c 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:4.18 0b 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:5.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:12.50 0a 3 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:11.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:13.49 0d 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:10.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:6.24 0d 1 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:7.18 0d 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:8.18 0a 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:4.19 0a 1 3 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:5.19 0d 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:11.26 0b 1 10 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:13.50 0b 3 2 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096

RAID group /aggr1/plex1/rg2 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch01:8.26 0a 1 10 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
parity switch01:4.27 0c 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:5.28 0c 1 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:11.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:7.19 0b 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:13.51 0c 3 3 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:6.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:10.22 0b 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:8.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:4.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:5.29 0c 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:11.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:7.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch01:13.52 0a 3 4 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:6.26 0d 1 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:10.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096

RAID group /aggr1/plex1/rg3 (normal)

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
dparity switch01:4.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
parity switch01:7.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:13.53 0b 3 5 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:6.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:10.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:8.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
data switch02:13.54 0d 3 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:6.28 0d 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:13.55 0a 3 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:13.56 0b 3 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch01:13.57 0c 3 9 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
data switch02:13.58 0d 3 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096

Checking the spare disks

test1*> aggr status -s

Pool1 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch01:13.38 0a 2 6 FC:B 1 FCAL 15000 272000/557056000 280104/573653840
spare switch02:13.33 0b 2 1 FC:A 1 FCAL 15000 272000/557056000 280104/573653840
spare switch01:12.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
spare switch01:13.60 0a 3 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
spare switch02:11.60 0d 3 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096

Pool0 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch03:2.19 0c 1 3 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:2.21 0c 1 5 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:12.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch03:15.44 0c 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch04:14.36 0b 2 4 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688

Status of the aggregate before offlining the plex

test1*> aggr status -v aggr1
Aggr State Status Options
aggr1 online raid_dp, aggr nosnap=off, raidtype=raid_dp,
mirrored raidsize=16,
64-bit ignore_inconsistent=off,
snapmirrored=off,
resyncsnaptime=60,
fs_size_fixed=off,
snapshot_autodelete=on,
lost_write_protect=on,
ha_policy=cfo, raid_cv=on,
thorough_scrub=off

Volumes: vol1, vol2, vol3

Plex /aggr1/plex0: online, normal, active
RAID group /aggr1/plex0/rg0: normal
RAID group /aggr1/plex0/rg1: normal
RAID group /aggr1/plex0/rg2: normal
RAID group /aggr1/plex0/rg3: normal

Plex /aggr1/plex1: online, normal, active
RAID group /aggr1/plex1/rg0: normal
RAID group /aggr1/plex1/rg1: normal
RAID group /aggr1/plex1/rg2: normal
RAID group /aggr1/plex1/rg3: normal

Offlining the plex

test1*> aggr offline aggr1/plex1
Plex ‘aggr1/plex1’ is now offline.

Status of the plex after it is offlined

test1*> aggr status aggr1
Aggr State Status Options
aggr1 online raid_dp, aggr
mirror degraded
64-bit

Volumes: vol1, vol2, vol3

Plex /aggr1/plex0: online, normal, active
RAID group /aggr1/plex0/rg0: normal
RAID group /aggr1/plex0/rg1: normal
RAID group /aggr1/plex0/rg2: normal
RAID group /aggr1/plex0/rg3: normal

Plex /aggr1/plex1: offline, normal, inactive
RAID group /aggr1/plex1/rg0: normal
RAID group /aggr1/plex1/rg1: normal
RAID group /aggr1/plex1/rg2: normal
RAID group /aggr1/plex1/rg3: normal

The aggr status –r of the aggregate remains unchanged. This will list all the disks on both the plexes. The only difference will be the ones highlighted.

test1*> aggr status -r aggr1
Aggregate aggr1 (online, raid_dp, mirror degraded) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal)
RAID group /aggr1/plex0/rg1 (normal)
RAID group /aggr1/plex0/rg2 (normal)
RAID group /aggr1/plex0/rg3 (normal)

Plex /aggr1/plex1 (offline, normal, inactive, pool1)
RAID group /aggr1/plex1/rg0 (normal)
RAID group /aggr1/plex1/rg1 (normal)
RAID group /aggr1/plex1/rg2 (normal)
RAID group /aggr1/plex1/rg3 (normal)

Destroying the plex

test1*> aggr destroy aggr1/plex1
Are you sure you want to destroy this plex? y
Plex ‘aggr1/plex1’ destroyed.

Checking the status after destroying the aggregate

test1*> aggr status aggr1
Aggr State Status Options
aggr1 online raid_dp, aggr
64-bit

Volumes: vol1, vol2, vol3

Plex /aggr1/plex0: online, normal, active
RAID group /aggr1/plex0/rg0: normal
RAID group /aggr1/plex0/rg1: normal
RAID group /aggr1/plex0/rg2: normal
RAID group /aggr1/plex0/rg3: normal

Checking the RAID status

The details of the RAID in plex0 is listed. plex1 is destroyed. The disks used in plex1 is now available as spares.

test1*> aggr status -r aggr1
Aggregate aggr1 (online, raid_dp) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal)
RAID group /aggr1/plex0/rg1 (normal)
RAID group /aggr1/plex0/rg2 (normal)
RAID group /aggr1/plex0/rg3 (normal)

The spares will be listed in the spares pool.

test1*> aggr status -s

Pool1 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch01:13.38 0a 2 6 FC:B 1 FCAL 15000 272000/557056000 280104/573653840
spare switch02:13.33 0b 2 1 FC:A 1 FCAL 15000 272000/557056000 280104/573653840
spare switch01:11.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:11.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:11.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:12.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
spare switch01:12.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.16 0a 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.19 0a 1 3 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.27 0c 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.17 0a 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.29 0c 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:7.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:7.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.17 0c 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.18 0a 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.26 0a 1 10 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:11.17 0d 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:11.26 0b 1 10 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:12.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.18 0b 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:5.16 0b 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:5.19 0d 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.18 0d 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.19 0b 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:8.16 0d 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:8.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:10.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:10.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:11.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:12.50 0a 3 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.51 0c 3 3 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.52 0a 3 4 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.55 0a 3 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.57 0c 3 9 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.60 0a 3 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
spare switch01:5.28 0c 1 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:6.23 0c 1 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.22 0b 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:11.59 0b 3 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:11.60 0d 3 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
spare switch02:12.49 0b 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.48 0d 3 0 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.49 0d 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.50 0b 3 2 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.53 0b 3 5 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.54 0d 3 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.56 0b 3 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.58 0d 3 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.22 0d 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.24 0d 1 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.26 0d 1 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.28 0d 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)

Pool0 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch03:2.19 0c 1 3 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:2.21 0c 1 5 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:12.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch03:15.44 0c 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch04:14.36 0b 2 4 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688

Destroying the aggregate completely

Note:
All volumes in the aggregate must be destroyed before destroying the aggregate. A message will come up stating that there are volumes in the aggregate and cannot be destroyed.

test1*> aggr offline aggr1
aggr offline: Cannot offline aggregate ‘aggr1’ because it contains one or more flexible volumes.

Destroy the aggregate with the aggr destroy <aggr name> command
test1*> aggr destroy aggr1
Are you sure you want to destroy this aggregate? y
Thu Jun 13 15:37:13 GMT [test1: raid.config.vol.destroyed:info]: Aggregate ‘aggr1’ destroyed.
Aggregate ‘aggr1’ destroyed.

Checking the status after the aggregate is destroyed

test1*> aggr status aggr1
aggr status: No aggregate named ‘aggr1’ exists

Check the status of the spares after both plexes were destroyed

test1*> aggr status -s

Pool1 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch01:13.38 0a 2 6 FC:B 1 FCAL 15000 272000/557056000 280104/573653840
spare switch02:13.33 0b 2 1 FC:A 1 FCAL 15000 272000/557056000 280104/573653840
spare switch01:11.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:11.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:11.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:12.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688
spare switch01:12.28 0a 1 12 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.16 0a 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.19 0a 1 3 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.27 0c 1 11 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:4.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.17 0a 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:5.29 0c 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:7.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:7.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.17 0c 1 1 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.18 0a 1 2 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.26 0a 1 10 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:8.29 0a 1 13 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:11.17 0d 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:11.26 0b 1 10 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:12.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.18 0b 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:4.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:5.16 0b 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:5.19 0d 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.18 0d 1 2 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.19 0b 1 3 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:7.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:8.16 0d 1 0 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch02:8.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch01:10.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:10.18 0c 1 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:11.27 0a 1 11 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:12.50 0a 3 2 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.51 0c 3 3 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.52 0a 3 4 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.55 0a 3 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.57 0c 3 9 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:13.60 0a 3 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096
spare switch01:5.28 0c 1 12 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch01:6.23 0c 1 7 FC:B 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.17 0b 1 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.22 0b 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.28 0b 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:10.29 0d 1 13 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:11.59 0b 3 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:11.60 0d 3 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096
spare switch02:12.49 0b 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.48 0d 3 0 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.49 0d 3 1 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.50 0b 3 2 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.53 0b 3 5 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.54 0d 3 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.56 0b 3 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:13.58 0d 3 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.22 0d 1 6 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.24 0d 1 8 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.25 0d 1 9 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.26 0d 1 10 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.27 0b 1 11 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch02:6.28 0d 1 12 FC:A 1 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)

Pool0 spare disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
——— —— ————- —- —- —- —– ————– ————–
Spare disks for block or zoned checksum traditional volumes or aggregates
spare switch03:2.19 0c 1 3 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:2.21 0c 1 5 FC:A 0 FCAL 15000 272000/557056000 274845/562884296
spare switch03:11.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:11.33 0a 2 1 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:11.44 0a 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:11.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:12.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:12.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch03:14.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:14.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:15.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:15.36 0c 2 4 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:15.44 0c 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch03:16.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:16.34 0c 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:16.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:17.32 0a 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:17.33 0a 2 1 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:17.34 0c 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:17.35 0a 2 3 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:17.45 0c 2 13 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:18.32 0c 2 0 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:18.34 0a 2 2 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:18.44 0c 2 12 FC:A 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:11.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:11.38 0d 2 6 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:12.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:12.42 0b 2 10 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:12.43 0d 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.32 0b 2 0 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.34 0d 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.35 0b 2 3 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.44 0d 2 12 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:13.45 0b 2 13 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:14.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:14.36 0b 2 4 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688
spare switch04:14.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:15.33 0b 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:15.34 0b 2 2 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:15.35 0d 2 3 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:16.33 0d 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:16.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:16.44 0d 2 12 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:18.33 0b 2 1 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:18.42 0b 2 10 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch04:18.43 0b 2 11 FC:B 0 FCAL 15000 560000/1146880000 560208/1147307688 (not zeroed)
spare switch03:16.49 0a 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch03:17.48 0a 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch03:18.48 0c 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch03:19.49 0c 3 1 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch03:20.48 0a 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch03:20.56 0c 3 8 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:16.48 0b 3 0 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:16.50 0b 3 2 FC:A 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:17.49 0b 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:17.50 0d 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:17.54 0b 3 6 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:18.49 0d 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:18.50 0b 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:19.48 0b 3 0 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:19.54 0b 3 6 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:20.49 0d 3 1 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:20.50 0b 3 2 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)
spare switch04:20.51 0d 3 3 FC:B 0 FCAL 15000 560000/1146880000 560879/1148681096 (not zeroed)

Zero the disks so that they are ready for the next disk operation
test1*> disk zero spares

Checking the zeroing process

test1*> aggr status –s

spare switch01:11.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688 (zeroing, 8% done)

This is now zeroing the disk. Once this is completed, it will be listed as
spare switch01:11.16 0c 1 0 FC:B 1 FCAL 15000 560000/1146880000 560208/1147307688

A message will come up once the zeroing is complete
Thu Jun 13 16:38:46 GMT [test1: raid.disk.zero.done:notice]: Disk switch01:11.16 Shelf 1 Bay 1 [NETAPP X292_S15K7560F15 NA00] S/N [3SL0GAM600009032XE08] : disk zeroing complete

Once the disks are zeroes, they are available for other operations and available as spares on the filer that owns it.

Leave a Reply


Hit Counter provided by technology news